TechWeb: Codes & Standards
Get the latest information about changes and updates in Codes and Standards that affect grilles, regsiters, diffusers, terminals, and fan coils
Changes in ARI 885-98 - Calculation for Room NC from Catalog Sound Power
ARI Standard 885 is the "Standard for Estimating Occupied Space Sound Levels in the Applications of Air Terminals and Air Outlets". The standard was developed by the Air-Conditioning and Refrigeration Institute (ARI) to establish a uniform industry procedure for estimating sound pressure levels in occupied spaces served by air terminals and/or air outlets. ARI 885 establishes consistent, industry-accepted practices for calculating room sound pressures used to determine the Noise Criteria (NC) of a terminal in a space.
NFPA 90A 2002 Revision and Raised Floor Air Distribution
The previous version of NFPA 90A, the 1999 Edition, did not address air diffusers designed for raised floor applications. The standard test method for NFPA compliance was NFPA 255, the NFPA equivalent to ASTM E84, also called the "tunnel test". This test required a 24 foot sample of product to be tested in a fire tunnel and was not applicable for discrete devices, such as the access floor diffusers.
LEED and Green Buildings
The U.S. Green Building Council, USGBC, developed the Leadership in Energy & Environmental Design, LEED TM , Green Building Rating System TM . LEED TM is a voluntary, consensus-based national standard for developing high-performance, sustainable buildings. The U.S. Green Building Council members represent all segments of the building industry and continue to update the program.
ARI Certified VAV Terminal Unit Program
TITUS actively participates in ARI's Certified VAV Terminal program each year and has since its inception in the late 1980s. The certification program's purpose is to ensure the accuracy of product performance data shown in ARI's Directory of Certified Applied Air-Conditioning Products. As a charter member of ARI, TITUS volunteered to be part of the preliminary independent tests. Results from the preliminary tests helped establish certification test guidelines and standards. Certification tests are conducted annually at an independent test facility where four units are sent for testing. As in years past, ARI used ITS/Intertek Testing Services located in Cortland, New York for testing.
![]() |
![]() |
| Titus is located at: 990 Security Row Richardson, TX 75081 Telephone: +1 972 699 1030 FAX: +1 972 918 8880 Click Here For A Map For answers to any and all product, application, installation, and other product related questions, please contact your local representative. titus@titus-hvac.com |
![]() |
| ISO (International Organization for Standardization) Titus is a recognized leader in the air distribution segment of the commercial HVAC industry. Titus products can be found in numerous prestigious projects worldwide, including the Guggenheim Museum in Spain, the Bank of China in Beijing and the International Space Station. |
| Thermal VAV Diffusers |
| Configurations |
| Features |
| Analog VAV DIffusers |
| Non-VAV Diffusers |
| VSR Recessed Hi-Rise |
| VSRM Recessed Hi-Rise Remote Master |
| VSRS Recessed Hi-Rise Remote Slave |
| VSM/VSS Recessed Master/Slave |
| VS Sound Power |
| AeroBalde Supply Grilles |
| AreoBalde Return Grilles |
| AreoBlade Options and Accessories |
| VAV Diffusers |
| Single/Dual Duct Terminals |
| Fan Powered Terminals |
| Terminals Unit Accessories |
| VAV Retrofit Terminals |
| Miscellaneous Terminals |
| Verticle Stack Series |
| Horizontal Basic Series |
| Vertical Basic Series |
| Horizontal High Output Series |
| Vertical High Output Series |
| Accessories |
| Horizontal Air Handler Belt Drive |
| Vertical Air Handler Belt Drive |
| Modular Air Handler Belt Drive |
| Rooftop Air Handler Belt Drive |
| HAB |
| VAB |
| MAB |
| RAB |
| AeroBalde Grilles |
| 300/350 Grilles |
| Specialized Grilles |
| Security Grilles |
| Security Products |
| GRD Accessories |
| FlowBar Diffusers |
| Critical Environment Diffusers |
| Access Floor Air Distribution |
| Linear Slot Ceiling Diffusers |
| Linear Slot Ceiling Plenums |
| Linear Bar Diffusers |
| Linear Louver Diffusers |
| Round Ceiling Diffusers |
| Perforated Ceiling Diffusers |
| Square Ceiling Diffusers |
| Rectangular Ceiling Diffusers |
| Nozzle & Specialty Diffusers |
| Concentric S / R Diffusers |
| TurboFuser |
| Fire Rated Diffusers |
| Grilles and Diffusers |
| Terminal, Controls |
| Fan Coils |
| Acoustical Aps |
| References |
| Glossary |
| Basic Principles of Air Distribution |
| Outlet Location and Selection |
Isothermal Air Jets |
| Supply Outlet Classifications |
| Perimeter Applications |
| ADPI-Air Diffusion Performance |
| Industrial Applications |
|
Other Grilles and Diffusers |
| Types of Terminals |
| Types of Controls |
Isothermal Air Jets |
| Control Operation in Terminals |
| Operation of a Velocity Controller |
| Fan Terminal Flow Control |
| Fan Speed Control |
|
ECM Motors - Fan Powered |
| Direct Digital Control |
| Sizing
Basic Teriminals from Capacity Tables |
| Typical Problems |
|
Some Basic Concepts |
| The Fan Law |
| Equations and Definitions |
| Types of Fan Coils |
| Heat Transfer |
Room Load Calculations |
| Psychometrics |
| Properties of Coils and Coils Design |
| Vertical Stack Risers |
| Controls and Value Packages |
| Modulinear - Aluminum |
| Modulinear Narrow Tee - Aluminum |
| Modulinear Diffuser Plenums - Steel |
![]() |